Filter dead temp sensors from SES health and recompute overall status
Xyratex HB-1235 enclosures have non-functional temperature sensor slots that report Unrecoverable/Unknown at 0°C. The SES header rolls these into UNRECOV=1, causing a false CRITICAL flag. Now we skip dead sensors (0°C + non-OK status) and derive overall_status from the actual parsed elements instead of the raw header counts.
This commit is contained in:
@@ -183,21 +183,6 @@ def _parse_ses_page02(text: str) -> dict:
|
||||
"voltages": [],
|
||||
}
|
||||
|
||||
# Parse header line for overall status:
|
||||
# INVOP=0, INFO=0, NON-CRIT=0, CRIT=1, UNRECOV=0
|
||||
header_match = re.search(
|
||||
r"INVOP=\d+,\s*INFO=\d+,\s*NON-CRIT=(\d+),\s*CRIT=(\d+),\s*UNRECOV=(\d+)",
|
||||
text,
|
||||
)
|
||||
if header_match:
|
||||
non_crit = int(header_match.group(1))
|
||||
crit = int(header_match.group(2))
|
||||
unrecov = int(header_match.group(3))
|
||||
if crit > 0 or unrecov > 0:
|
||||
result["overall_status"] = "CRITICAL"
|
||||
elif non_crit > 0:
|
||||
result["overall_status"] = "WARNING"
|
||||
|
||||
# Split into element type sections.
|
||||
# Each section starts with "Element type: <type>"
|
||||
sections = re.split(r"(?=\s*Element type:)", text)
|
||||
@@ -250,6 +235,12 @@ def _parse_ses_page02(text: str) -> dict:
|
||||
elif "temperature" in element_type:
|
||||
temp_match = re.search(r"Temperature=\s*([\d.]+)\s*C", elem_text)
|
||||
temp = float(temp_match.group(1)) if temp_match else None
|
||||
# Skip dead/disconnected sensors: 0°C with a non-OK status
|
||||
# is a non-functional sensor slot, not an actual reading.
|
||||
if (temp is None or temp == 0) and status.lower() in (
|
||||
"unrecoverable", "unknown", "not available",
|
||||
):
|
||||
continue
|
||||
result["temps"].append({
|
||||
"index": idx,
|
||||
"status": status,
|
||||
@@ -267,4 +258,21 @@ def _parse_ses_page02(text: str) -> dict:
|
||||
"voltage": voltage,
|
||||
})
|
||||
|
||||
# Derive overall_status from the actual parsed elements rather than
|
||||
# the raw SES header, which counts dead/disconnected sensors as
|
||||
# UNRECOV and inflates severity.
|
||||
all_statuses = (
|
||||
[e["status"] for e in result["psus"]]
|
||||
+ [e["status"] for e in result["fans"]]
|
||||
+ [e["status"] for e in result["temps"]]
|
||||
+ [e["status"] for e in result["voltages"]]
|
||||
)
|
||||
status_lower = [s.lower() for s in all_statuses]
|
||||
if any(s in ("unrecoverable", "critical") for s in status_lower):
|
||||
result["overall_status"] = "CRITICAL"
|
||||
elif any(s in ("noncritical", "non-critical", "warning") for s in status_lower):
|
||||
result["overall_status"] = "WARNING"
|
||||
elif any(s not in ("ok", "unknown") for s in status_lower):
|
||||
result["overall_status"] = "WARNING"
|
||||
|
||||
return result
|
||||
|
||||
Reference in New Issue