Commit Graph

2 Commits

Author SHA1 Message Date
ea045433e5 Split host-poller into separate env (IPMI/CPU) and drive (SMART) loops
Two concurrent loops in one process sharing the lock + hardware gate (IPMI and
SMART never run concurrently) but on separate schedules: env every
HOST_ENV_INTERVAL (60s, responsive inlet/CPU) and drives every
HOST_DRIVE_INTERVAL (300s, gentle SMART). Each loop has its own heartbeat
(env_meta/drive_meta) + restart-storm guard.
2026-06-16 18:50:16 +00:00
1839e9d5f2 Add host-poller: chassis IPMI/iDRAC + CPU + on-metal drive temps
New third producer container (host-poller) owning the server chassis
subsystem, separate from the SAS-shelf poller:
- services/host_sensors.py: in-band IPMI (ipmitool sdr) for Inlet/Exhaust/etc.
  + CPU package temps from coretemp hwmon
- host_poller.py: own single-instance lock + heartbeat (host_poll keys),
  restart-storm guard, paced; writes jbod:host_sensors + jbod:host_drives
- move host/on-metal drive collection off the SAS poller to host-poller
  (reads jbod:zfs_map for annotation)
- store: generalized lock/meta with a key param; host_sensors + host-poll keys
- mqtt_publisher: publish env/CPU/host-drive temps as entities on the hub
  device (JBOD Monitor)
- Dockerfile host-poller target (ipmitool+smartmontools); compose.infra adds
  host-poller; build.sh gains host-poller/all
2026-06-16 18:27:56 +00:00