Xyratex HB-1235 enclosures have non-functional temperature sensor slots that report Unrecoverable/Unknown at 0°C. The SES header rolls these into UNRECOV=1, causing a false CRITICAL flag. Now we skip dead sensors (0°C + non-OK status) and derive overall_status from the actual parsed elements instead of the raw header counts.